Operation, cont’d

Problem

Possible cause

Solution

Output resolution

Input resolution too

The IN1404XT can only scale up.

cannot be increased.

high.

Connect a signal with a lower

 

 

active area.

Active pixels and/or active lines may be too high.

Select Input>Advanced>Active Area and reduce the active lines and/or active pixels to match the input signal.

Input aspect ratio

Output resolution too

The IN1404XT can only scale up.

cannot be selected.

low.

Select Output>Resolution and

 

 

increase the resolution until the

 

 

desired aspect ratio becomes

 

 

available.

 

 

 

 

Image size too high

Select Output>Size and decrease

 

 

the image size.

 

 

 

 

 

Select a different available aspect

 

 

ratio.

 

 

 

The output size

Output resolution too

Select Output>Resolution and

cannot be increased.

high.

decrease the resolution.

 

 

 

Multiple faint

Input total pixels

Select Input>Advanced>Total

vertical lines appear.

setting incorrect.

Pixels and experiment with

 

 

settings until the lines move

 

 

completely out of view or only

 

 

one remains. See Single faint

 

 

vertical line appears, below, if

 

 

necessary.

 

 

 

Single faint vertical

Input phase setting

Select Input>Phase and

line appears.

incorrect.

experiment with settings until the

 

 

line moves completely out of view.

 

 

 

The entire image is

Sharpness setting too

Select Video>Sharpness and

too soft.

low.

increase the sharpness setting.

 

 

 

 

Noise filter incorrect.

Select Video>Noise Filter and

 

 

select a different setting.

 

 

 

 

The refresh rate may

Select Output>Refresh Rate and

 

be too high.

lower the refresh rate.

 

 

 

Some characters are

Total pixels setting

Select Input>Advanced>Total

too soft.

incorrect.

Pixels and experiment with

 

 

settings until the characters are

 

 

sharp.

 

 

 

 

Input phase setting

Select Input>Phase and

 

incorrect.

experiment with settings until the

 

 

characters are sharp.

 

 

 

Only the top half of

(Non-interlaced video)

Select Input>Advanced>Scan Type

the image displays.

Scan type incorrect.

and select Interlaced to toggle the

 

 

setting off.

 

 

 

Image jitters up and

(Interlaced video)

Select Input>Advanced>Scan Type

down.

Scan type incorrect.

and select Interlaced to toggle the

 

 

setting on.

 

 

 

3-34 IN1404XT Video Scaler and Switcher • Operation