Problem

Possible cause

Solution

Total pixels setting

Active pixels setting

Select Picture>Advanced>Active

cannot be increased.

may be too low.

Pixels and increase the setting to

 

 

match the input signal.

 

 

 

 

Horizontal start

Select Picture>Advanced>H

 

may be too high.

Start and reduce the setting to

 

 

match the input signal.

 

 

 

 

Output resolution may

Press the front panel Output Rate

 

be too low.

button to select a setting that is

 

 

greater than or equal to the active

 

 

area.

 

 

 

Active lines setting

Vertical start

Select Picture>Advanced>

cannot be increased.

may be too high.

V Start and reduce the setting to

 

 

match the input signal.

 

 

 

 

Output resolution may

Press the front panel Output Rate

 

be too low.

button to select a setting that is

 

 

greater than or equal to the active

 

 

area.

 

 

 

Horizontal start

Total pixels setting

Select Picture>Advanced>Total

setting cannot be

may be too low.

Pixels and increase the setting to

increased.

 

match the input signal.

 

 

 

 

Active pixels setting

Select Picture>Advanced>Active

 

may be too high.

Pixels and reduce the setting to

 

 

match the input signal.

 

 

 

Vertical start.

Active lines setting

Select Picture>Advanced>Active

 

may be too high.

Lines and reduce the setting to

 

 

match the input signal.

 

 

 

IN1508 Scaling Presentation Switcher • Operation 3-43