Symbol Definitions

Symbol Definitions

] = CR/LF (carriage return + line feed) (hex 0D 0A)

}= Soft carriage return (no line feed, hex 0D)

(For web browser commands, use the [pipe] character instead of the soft return.)

= Pipe (vertical bar) character

= Space

24= The 24 superscript indicates commands that give an E24 (privilege violation) message if you are not logged in at the administrator level.

E= Escape key (hex 1B) (For web browsers, use W instead of E.) X! = Power receptacle (1-4)

X#

= Greenwich Mean Time (GMT) offset value

 

 

(12.00 to +14.00) represents the time difference in hours and minutes (±hh:mm) relative to Greenwich, England. The

 

 

plus sign and leading zero are optional. For example, 5:30 = +05:30.)

X%

= On or Off status

 

 

 

0 = off or disabled

 

 

 

1 = on or enabled

 

X^

=

Dirty memory status

 

 

 

1 = RAM needs to be saved to flash memory.

 

 

0 = RAM has been saved to flash (OK to power off or reset).

X1! = Version (typically listed to two decimal places, that is, n.nn)

X1@

= Unit name. The name of the PC1 is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9),

 

 

and minus sign or hyphen (-). No blank or space characters are permitted as part of a name. No distinction is made

 

 

between upper and lower case.

 

 

NOTE: The first character must be a letter. The last character must not be a minus sign or hyphen (-).

X1#

= Local date and time format

 

 

 

Set format (MM/DD/YY-HH:MM:SS).

 

 

Example: 11/18/03-10:54:00.

 

 

Read format (day of week, day month year HH:MM:SS).

 

 

Example: Tue, 18 Nov 2011 18:19:33.

X1$

= IP address (nnn.nnn.nnn.nnn). Leading zeros in each of four fields are optional in setting values, and they are

 

 

suppressed in returned values.

X1%

= E-mail domain name (for example: extron.com)

X1*

=

Hardware (MAC) address (xx-xx-xx-xx-xx-xx).

X1(

= Subnet mask (nnn.nnn.nnn.nnn). Leading zeros are optional in setting values in each of four fields, and they are

 

 

suppressed in returned values.

X2@

 

For verbose response mode:

 

 

 

0 = clear or none

 

 

 

1 = verbose mode

 

 

 

2 = tagged responses for queries

 

 

3 = verbose mode and tagged responses for queries

 

 

Default = 0

 

 

 

NOTE: If tagged responses are enabled, all read commands return the constant string plus the data, like

 

 

setting the value does.

 

 

Example:

 

 

 

Command:

E CN }

 

 

Response:

Ipn • X1@

X3#

= Password (minimum length = 4 characters; maximum length = 12 characters.

 

 

No special characters are allowed.

IPL T PCS4 • SIS Programming and Control 46