Command

ASCII (Telnet)

URL Encoded (Web)

Response

(Host to Switcher)

(Host to Switcher)

(Switcher to Host)

 

 

 

Firmware Version, Part Number, and Information Requests

 

Query firmware version

Q

Q

X1! ]

Query firmware information

1Q

1Q

X1! ]

Query bootstrap version

2Q

2Q

X1! ]

Query factory firmware version

3Q

3Q

X1! plus (web version

 

 

 

model UL date and

 

 

 

time) ]

Query updated firmware version

4Q

4Q

X1! plus (web version

 

 

 

model UL date and

 

 

 

time) ]

Query verbose version information

0Q

0Q

Sum of responses from

 

 

 

2Q, 3Q, and 4Q ]

NOTE: An asterisk (*) after a version number indicates the version that is currently running. Question marks (?.??) indicate that only the factory firmware version is loaded. A caret (^) indicates the firmware version that should be

running; however, a mode 1 reset was executed and the factory default firmware version is currently loaded. An

exclamation point (!) indicates corrupted firmware.

Request interface part number

N

N

60-544-07 or

 

 

 

60-544-09]

Request model name

1I

1I

IPL T PCS4 or

 

 

 

IPL T PCS4i]

Request model description

2I

2I

Lists four switched

 

 

 

110 VAC or 220 VAC

 

 

 

receptacles with current

 

 

 

threshold sensing.]

Request system memory usage

3I

3I

Number of bytes and

 

 

 

Kbytes used out of

 

 

 

the number of total

 

 

 

Kbytes]

Request user memory usage

4I

4I

Number of bytes and

 

 

 

Kbytes used out of

the number of total Kbytes]

E-mail Commands

Configure e-mail events (mailbox)24

Example:

View e-mail events (mailbox)

Send e-mail events (file named in mailbox)24

E X4%

X4^ X4&

CR

}

W

X4%

%2C

X4^

%2C

X4&

CR

Ipr X4%,X4^,X4& ]

,

,

 

 

 

 

 

E5,jdoe@extron.com,7.emlCR} W5%2Cjdoe%40extron%2Ecom%2C7%2EemlCR

Ipr5,jdoe@extron.com,7.eml]

E X4% CR}

W X4% CR

X4^,X4& ]

E X4% SM}

W X4% SM

Eml X4^ ]

Send e-mail (using different file)24

E X4%,X7),X4& SM}

W X4% %2C X7) %2C X4& SM

Eml X4^ ]

 

 

 

 

 

Web Browser-specific Commands

 

 

 

 

Read response from last URL cmd

E UB}

W UB

Response from

 

 

 

command]

Mail Server Setup Commands

 

 

 

 

 

Set mail server IP, unit domain

E X1$,X1% CM}

W X1$ %2C X1% CM

Ipm

X1$

X1% ]

name24

 

 

 

,

View mail server IP, unit domain

E CM}

W CM

X1$,X1% ]

name

 

 

 

 

 

IPL T PCS4 • SIS Programming and Control 50

Page 56
Image 56