Extron electronic IPL T PCS4i Troubleshooting, Power Connections, Connecting to the IP Address

Models: IPL T PCS4 IPL T PCS4i

1 69
Download 69 pages 31.92 Kb
Page 46
Image 46
Figure 33. Connecting to the IP Address

3.At the <to> prompt, enter the IP address of the PCS4 unit. (The default IP address is 192.168.254.254. If the address was changed in the setup or configuration process, use the new address.) Telnet defaults to port 23.

Figure 33. Connecting to the IP Address

4.If passwords were set up for the connected system, you are prompted to log in as an administrator or a user. Otherwise, the system responds with a carriage return and line feed (<cr/lf>).

5.Once you are connected, you can enter SIS commands as desired.

6.When you are finished entering commands to the interface, press < Ctrl + ] > at the command prompt to exit Telnet.

Troubleshooting

Turn on the equipment in the following order:

1.The PCS4 power control interface

2.The power receptacles on the PCS4

3.The connected output devices

If the output A/V device cannot be powered on, check the following:

Power Connections

1.Make sure that the receptacle for each device is receiving power. The red Power LED of the receptacle lights if the receptacle is powered on. If necessary, press the receptacle button to apply power.

2.Ensure that all devices are plugged in properly to the rear panel of the PCS4 and switched on if applicable.

IPL T PCS4 • HTML Configuration and Control 40

Page 46
Image 46
Extron electronic IPL T PCS4i manual Troubleshooting, Power Connections, Connecting to the IP Address