SET REFERENCE
STANDBY FULL

Setting the Standby power threshold 1. Power off the attached device.

2. Press and hold the Standby button (shown at right).

3. While holding down the Standby button, press and release the receptacle button for the same device for which you set the Full threshold. The Standby LED for the selected receptacle blinks twice and remains lit.

1

F

Standby

LED

S

Receptacle Button

4.Release the Standby button.

5.Repeat steps 1 through 9 for any other receptacles to which you have connected devices to be controlled through the PCS4.

NOTE: Settings that are made via the front panel for power output receptacles

and reference thresholds take approximately two minutes to be stored in

memory. If you recycle power too soon after settings have been made, the settings are lost.

These threshold settings are preserved if the PCS4 AC power is recycled or if power is removed from an attached device. For example:

If the receptacle

is set to...

And the power level...

The receptacle...

Full

drops below the stored threshold

F (Full) led shuts off, and the

S (Standby) LED lights.

 

 

 

drops below the stored Standby

S LED shuts off.

Standby

threshold

 

 

exceeds the stored Standby threshold

F LED lights.

To indicate that the configuration has been saved, both the Standby LED and the Full LED light and remain lit when those thresholds are selected.

None and Not Set thresholds

When a Full or Standby reference threshold has been set for a receptacle at some time, and neither threshold is detected, a threshold status of None appears on the web page or can be the response to SIS queries. None also appears if the receptacle is powered off. The None threshold is a state that is detected; it cannot be set manually.

If a receptacle has never been set to a Full or Standby reference threshold, its threshold status is shown as Not Set on the web page and in response to SIS queries. Not Set is the default setting for reference thresholds.

IPL T PCS4 • Front Panel Features and Operation 11

Page 17
Image 17
Extron electronic IPL T PCS4 None and Not Set thresholds, If the receptacle Is set to Power level Receptacle Full, Standby