Part Numbers and Accessories

Included Parts

These items are included in each order for an IPL T PCS4 or IPL T PCS4i interface:

Included Parts

Part Number

IPL T PCS4 or

60-544-07

IPL T PCS4i

60-544-09

Rubber feet (self-adhesive) (4)

 

 

 

2-pole captive screw connector (1)

 

14 AWG IEC power cord (IPL T PCS4 only)

Tweeker (small screwdriver)

IPL T PCS4 and IPL T PCS4i User Guide

Power cord caution card

Optional Accessories

These items are optional for the IPL T PCS4 or the IPL T PCS4i:

Optional Accessories

Part Number

RSU 129 Universal Rack Shelf Kit

60-190-01

RSB 129 Basic Rack Shelf

60-604-02

 

 

MBU 125 Under Desk Mounting Kit

70-077-01

Mounting the IPL T PCS4 Interface

The IPL T PCS4 can be set on a table, mounted on a rack shelf, or mounted under furniture such as a desk, podium, or tabletop.

Tabletop Use

Four self-adhesive rubber feet are included with the PCS4. For tabletop use, attach one foot at each corner of the bottom side of the unit, and place the PCS4 in the desired location.

Rack Mounting

UL guidelines for rack mounting

The following Underwriters Laboratories (UL) guidelines pertain to the installation of the

IPL T PCS4 in a rack:

Elevated operating ambient temperature — If the equipment is installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, consider installing the equipment in an environment compatible with the maximum ambient temperature (TMA) specified by the manufacturer.

Reduced air flow — Install the equipment in the rack so that the amount of air flow required for safe operation of the equipment is not compromised.

Mechanical loading — Mount the equipment in the rack so that uneven mechanical loading does not create a hazardous condition.

IPL T PCS4 • Reference Material 56