Command and Response Table for SIS Commands

Command

ASCII (Telnet)

URL Encoded (Web)

Response

(Host to Switcher)

(Host to Switcher)

(Switcher to Host)

 

 

 

 

Power Receptacle Control / Current Sense

 

 

Turn receptacle power on

E X!*1PC}

W X! %2A 1PC

Cpn X!•Ppc1]

Turn receptacle power off

E X!*0PC}

W X! %2A 0PC

Cpn X!•Ppc0]

View receptacle power status

E X! PC}

W X! PC

X% ]

Query receptacle current status

E X! PS}

W X! PS

X( ]

Group receptacles

E X1)1 X1)2 X1)3 X1)4 GP}

W X1)1 X1)2 X1)3 X1)4 GP

Pgp X1)1 X1)2 X1)3 X1)4 ]

Ungroup receptacles

E 0000GP}

W 0000GP

Pgp0000]

View receptacles grouping

E GP}

W GP

X1)1 X1)2 X1)3 X1)4 ]

Set power up delay

E X1^ DT}

W X1^ DT

Pdt X1^ ]

View power up delay

E DT}

W DT

X1^ ]

Set individual full threshold

E X!*2TH}

W X! %2A 2TH

Ptf X! ]

Set individual standby threshold

E X!*1TH}

W X! %2A 1TH

Pts X! ]

Clear individual threshold

E X!*0TH}

W X! %2A 0TH

Ptc X! ]

View threshold setting for all ports

E TH}

W TH

X(1,X(2,X(3,X(4 ]

Set Executive mode on

1X

1X

Exe1]

Set Executive mode off

0X

0X

Exe0]

View Executive mode

X

X

X% ]

 

 

 

Power Receptacle Monitoring and Alarm Functions

 

 

Set alarm conditions

E X!*X70!*X70@*X70# SA}

 

 

 

 

W X! %2A X70! %2A X70@ %2A X70# SA

 

 

Ast X!*X70!*X70@*X70#*X70$*X70% ]

View alarm conditions

E X!*SA}

W X! SA

 

 

 

 

X70!*X70@*X70#*X70$*X70% ]

Monitoring enable or disable

E X!*X70$ SA}

W X! %2A X70$ SA

 

 

 

Ast X!*X70!*X70@*X70#*X70$*X70% ]

Set Alarm mode

E X70^*X70&*X70**X70**X71) MA}

 

 

 

W X70^ %2A X70& %2A X70* %2A X70* %2A X71) MA

 

 

Arl X70^*X70&*X70**X70**X71) ]

View Alarm mode

E MA }

WMA

 

 

 

 

X70^*X70&*X70**X70**X71) ]

Power Receptacle Scheduling

 

 

 

Set scheduling

E X!*X71!*X%*X71@ SS}

W X! %2A X71! %2A X% %2A X71@ SS

 

 

 

Set X!*X71!*X%*X71@ ]

View scheduling

E X!*X71!*X% SS}

W X! %2A X71! %2A X% SS

X71@ ]

Alarm Relay Functions

 

 

 

Turn alarm relay ON

1*1O}

1 %2A 1O

Cpn1Rly1]

Turn alarm relay OFF

1*0O}

1 %2A 0O

Cpn1Rly0]

View alarm relay state

1O}

1O

X% ]

Pulse relay

1*3*X6# O}

1 %2A 3 %2A X6# O

Cpn1Rly1] or

 

 

 

Cpn1Rly0]

Toggle relay

1*2O }

 

Cpn1Rly1] or

 

 

 

Cpn1Rly0]

Ethernet Data Port Commands

 

 

 

Set current connected port

E 0*X6( TC}

W0 %2A X6( TC

Pti0*X6( ]

timeout

 

 

 

View current connected port

E 0TC}

W0TC

X6( ]

timeout

 

 

 

Set global IP port timeout

E 1*X6( TC}

W1 %2A X6( TC

Pti1*X6( ]

View global IP port timeout

E 1TC}

W1TC

X6( ]

IPL T PCS4 • SIS Programming and Control 49

Page 55
Image 55
Extron electronic IPL T PCS4 Command and Response Table for SIS Commands, Power Receptacle Monitoring and Alarm Functions