Extron electronic IPL T PCS4i manual Setting Up the Computer Using a Web Browser

Models: IPL T PCS4 IPL T PCS4i

1 69
Download 69 pages 31.92 Kb
Page 23
Image 23
Figure 10. Screen Showing the Ping Command

The response should be the new IP address of the PCS4, as shown below.

Figure 10. Screen Showing the Ping Command

You can reconnect using either Telnet or a web browser to verify that the update was successful.

6.After verifying that the IP address change was successful, issue the arp -dcommand at the DOS prompt to remove the address from the ARP table. For example:

arp -d 10.13.170.15

A space must separate arp from the hyphen (-).

Setting Up the Computer Using a Web Browser

To set up the PCS4 using a web browser, you must temporarily configure the computer to communicate with the interface. Then you can change the PCS4 default settings (IP address, subnet mask, and [optionally] administrator name and password) in order to use the unit on an intranet (LAN) or on the Internet (WAN). After you have set up the PCS4 for network communication, you can reset the computer to its original network configuration.

IPL T PCS4 LAN port defaults:

PCS4 IP address: 192.168.254.254

Gateway IP address: 0.0.0.0

Subnet mask: 255.255.0.0

DHCP: Off

Link speed and duplex level: Auto detected

If you use an existing Ethernet LAN intranet, your network administrator can provide you with a unique IP address for the PCS4 or confirm whether you need to set up the PCS4 for Dynamic Host Configuration Protocol (DHCP) to have an address assigned automatically when you sign on.

IPL T PCS4 • HTML Configuration and Control 17

Page 23
Image 23
Extron electronic IPL T PCS4i manual Setting Up the Computer Using a Web Browser, Screen Showing the Ping Command