1BluX1(]

X@BrtX1!]

A front panel color brightness adjustment has occurred. X@ is the output number tied to the adjusted input and X1! is the brightness variable.

X@ConX1!]

A front panel contrast adjustment has occurred. X@ is the output number tied to the adjusted input and X1! is the contrast variable.

X@HszX1@]

A front panel horizontal size adjustment has occurred. X@ is the output number and X1@ is the size variable.

X@VszX!@]

A front panel vertical size adjustment has occurred. X@ is the output number and X1@ is the size variable.

X@HphX1#]

A front panel horizontal centering adjustment has occurred. X@ is the output number and X1# is the centering variable.

X@VphX1#]

A front panel vertical centering adjustment has occurred. X@ is the output number and X1# is the centering variable.

X@BltX1$]

A front panel top line blanking adjustment has occurred. X@ is the output number and X1$ is the blanking variable.

X@BlbX1$]

A front panel bottom line blanking adjustment has occurred. X@ is the output number and X1$ is the blanking variable.

X@PhsX1%]

A front panel pixel phase adjustment has occurred. X@ is the output number and X1% is the pixel phase variable.

X@DhzX1^]

A front panel horizontal detail filter adjustment has occurred for the RGB or component video input tied to output X@. X1^ is the filter variable.

X@DvzX1&]

A front panel vertical detail filter adjustment has occurred for the RGB or component video input tied to output X@. X1& is the filter variable.

X@DvzX1&]

A front panel horizontal detail filter adjustment has occurred for the S-video or composite video input tied to output X@. X1& is the filter variable.

1BluX1(]

The blue-only mode has been turned on or off from the front panel for one or both outputs. X1( is the on/off status for the either or both outputs. The leading “1” is meaningless.

1FilX1(]

The edge enhancement mode has been turned on or off from the front panel for one or both outputs. X1( is the on/off status for the either or both outputs. The leading “1” is meaningless.