Extron electronic MVX PLUS 128 manual Installation, cont’d, RS-232/RS-422 connection

Models: MVX PLUS 128

1 148
Download 148 pages 51.92 Kb
Page 20
Image 20
Installation, cont’d

Installation, cont’d

dConnections for balanced and unbalanced audio outputs — These 3.5 mm, 5-pole captive screw connectors output the selected unamplified, line level audio. Connect audio devices, such as an audio amplifier or powered speakers. See figure 2-4 to properly wire an output connector.

Tip Figure 2-4 — Captive screw connector wiring for audio output See caution RS-232/RS-422 connection Sleeve Figure 2-5 — RS-232/RS-422 connector Tip 2-4 MVX Plus 128 VGA Matrix Switchers • Installation

See caution Manual background

Tip

Ring

Sleeve (s)

Tip

Ring

Unbalanced Output

Balanced Output

Figure 2-4 — Captive screw connector wiring for audio output

CConnect the sleeve to ground (Gnd). Connecting the sleeve to a negative (-) terminal will damage the audio output circuits.

The volume level for each output can be individually set via the front panel or Ethernet or RS-232/RS-422 control. See chapter 3, Operation; chapter 4, Programmer’s Guide; chapter 5, Switcher Software; and chapter 6, HTML Operation for details.

RS-232/RS-422 connection

eRS-232/RS-422 connector — Connect a host device, such as a computer, touch panel control, or RS-232 capable PDA to the switcher via this 9-pin D connector for serial RS-232/RS-422 control (figure 2-5).

REMOTE

 

 

 

Pin RS-232 Function

RS-422 Function

1

 

RS232/RS422

1

Not used

Not used

6

2

TX

Transmit data

TX–

Transmit data (–)

 

 

 

3

RX

Receive data

RX–

Receive data (–)

 

 

 

5

9

 

4

Not used

Not used

 

5

Gnd

Signal ground

Gnd

Signal ground

 

 

 

 

 

 

 

 

6

Not used

Not used

 

 

 

7

Not used

RX+

Receive data (+)

 

 

 

8

Not used

TX+

Transmit data (+)

 

 

 

9

Not used

Not used

Figure 2-5RS-232/RS-422 connector

See chapter 4, Programmer’s Guide, for definitions of the SIS commands (serial commands to control the switcher via this connector) and chapter 5, Matrix Software, for details on how to install and use the control software.

NThe switcher can support either the RS-232 or RS-422 serial communication protocol, and operate at 9600, 19200, 38400, or 115200 baud rates.

See Selecting the RS-232/RS-422 protocol and baud rate in chapter 3, Operation, to configure the RS-232/RS-422 port from the front panel.

If desired, connect an MKP 2000 or MKP 3000 remote control panel to the switcher’s RS-232/RS-422 connector. Refer to the MKP 2000 Remote Control Panel User’s Manual and the MKP 3000 User’s Manual for details.

2-4 MVX Plus 128 VGA Matrix Switchers • Installation