NWhen the control program is connected to the switcher via the
Matrix IP Address field
The Matrix IP Address field contains the IP address of the connected matrix switcher. This value is encoded in the flash memory in the switcher.
Valid IP addresses consist of four
255.Leading zeroes, up to 3 digits total per field, are optional. Values of 256 and above are invalid.
The default address is 192.168.254.254, but if this conflicts with other equipment at your installation, you can change the IP address to any valid value.
NEditing the Extron IP address while connected via the Ethernet port can immediately disconnect the user from the matrix switcher. Extron recommends editing this field using the
Edit this field as follows:
1. | Click in the Matrix IP address field. The graphic cursor becomes a text cursor. |
2. | Edit the address as desired. |
3. | Press the Tab key on the keyboard or click in another field to exit the Matrix IP |
| Address field. |
4. | Click the Take button to make the address change take affect. |
Extron Name/Descriptor field
The Extron Name/Descriptor field contains the name used as the “from” information when the MVX Plus 128 switcher
NThe following characters are invalid in the Extron Name/Descriptor field: {space} + ~ , @ = ‘ [ ] { } < > ’ “ ; : \ and ?.
Edit this field as follows:
1. | Click in the Extron name/descriptor field. The graphic cursor becomes a text |
| cursor. |
2. | Edit the name as desired. |
3. | Press the Tab key on the keyboard or click in another field to exit the Extron |
| Name/Descriptor field. |
4. | Click the Take button to make the name change take effect. |