Extron electronic MVX PLUS 128 Command/response table for SIS commands continued, ASCII command

Models: MVX PLUS 128

1 148
Download 148 pages 51.92 Kb
Page 85
Image 85
Information requests (continued)

Command/response table for SIS commands (continued)

Command

 

 

ASCII command

Response

Additional

 

 

 

 

 

 

(host to switcher)

(switcher to host)

description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Information requests (continued)

 

 

 

 

 

 

 

 

 

Query controller firmware

0Q

X1(-X2)-X2)]

Provide a detailed status

version (verbose)

 

 

 

 

 

 

 

 

 

 

 

of the Ethernet protocol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

firmware, the controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

firmware, and any firmware

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

upgrade. The firmware that

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

is running is marked by

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

an asterisk (*). A caret (^)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

indicates that the firmware

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

has a bad checksum or an

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

invalid load. ?.?? indicates

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

that firmware is not loaded.

Response description:

 

 

Ethernet protocol firmware version-controller firmware version-updated firmware version]

Example:

 

 

0q

 

 

 

 

 

 

 

 

 

 

 

 

Description

 

 

 

* indicates the version running

Upload date and time

 

 

 

 

 

 

 

 

 

Response: 1.23-0.14(0.20-32x32 Series - , 00 2000 00:00:00 GMT)-0.25*(0.24-32x32 Series

-Thu, 20 Mar 2003 16:39:21 GMT)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ethernet protocol

 

 

CrossPoint/MAV firmware version

 

 

 

 

 

Updated firmware version

firmware

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Request system status

 

 

S

X2$•X2$•X2$•X2$•X2$•X2%]

Response description:

 

 

+3.3V+5V-5V+15V-15Vtemperature (degrees fahrenheit)]

Example:

 

 

 

 

 

-15V power system at -15.15V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.29•5.04•-5.14•15.27•-15.15•120.20

 

 

 

 

 

 

 

 

 

3.3V power system

 

at 3.29V

 

 

 

 

 

 

 

 

 

 

 

 

Temperature 120.20 degrees

 

 

 

MVX Plus 128 VGA Matrix Switchers • Programmer’s Guide 4-15

Page 85
Image 85
Extron electronic MVX PLUS 128 Command/response table for SIS commands continued, ASCII command, Response, Additional