Command/Response Table for SIS Commands

SISProgramming and Control, cont’d

Command/Response Table for SIS Commands

Symbol definitions

]= CR/LF (carriage return/line feed) (hex 0D 0A)

}= Carriage return (no line feed, hex 0D)

(use the pipe character, , instead for Web browser commands)

= Space character

= Pipe (vertical bar) character

E= Escape key (hex 1B)

 

 

(use W instead of Esc for Web browsers)

 

 

 

 

X!

=

Input number

01

– 12

X@

= Input number (for tie)

00

– 12 (00 = untied)

X#

=

Output number

01

– 08

X$

=

Numeric dB value

–18 to +24 (45 steps of gain or attenuation)

X%

=

Audio gain

0

– 24

(1 dB/step)

X^

=

Audio attenuation

1

– 18

(1 dB/step)

X&

=

Volume adjustment range

0

– 64

(1 dB/step except for 0-to-1, which is 34 dB)

 

 

 

(see the table on page 4-9)

X*

= Room # (for room presets)

10 max. (each can have up to 10 presets (X1@s) assigned)

NA Room is a subset of operator-selected outputs that relate to each other. The MVX Plus 128 switcher supports up to 10 rooms, each of which can consist of from 1 to 16 outputs.

X(

=

Mute, executive mode, power supply

(0 = off/not OK, 1 = on/OK)

X1)

=

Group # (for I/O grouping)

1 through 4 groups (0 = no group)

X1! =

Global preset #

32 maximum (0 = current configuration)

X1@ =

Room preset #

10 maximum (0 = current configuration for room)

NA Room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from memory, it becomes the current configuration.

X1# =

RGB delay interval

Delay in ½ second increments (10 maximum)

X1$ =

Video/audio mute:

0

= no mutes

 

 

1

= video mute

 

 

2

= audio mute

 

 

3

= video and audio mute

X1% =

Sync frequency

xxx.xx (frequency in Hz (V) or kHz (H))

X1( =

Firmware version number to second decimal place (x.xx)

 

 

X2) =

Verbose firmware version-description-upload date/time. See page 4-15.

X2# =

Name

12 characters maximum for global and room preset names

 

 

11 characters maximum for room names

 

 

Upper- and lower-case alphanumeric characters and

 

 

_ : = / and spaces are valid.

NThe following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : \ and ?.

X2$

=

Voltage

Positive or negative voltage and magnitude

X2%

=

Temperature

Degrees Fahrenheit