Extron electronic MVX PLUS 128 manual Command/response table for SIS commands continued

Models: MVX PLUS 128

1 148
Download 148 pages 51.92 Kb
Page 81
Image 81
Save, recall, and directly write presets
Clear all ties in preset X1!. The tie all (!), tie RGBHV (&), tie video (%), and tie audio ($) commands are all valid. Clear all ties in preset 27.
Brackets are shown to separate ties for clarity only. Create global preset 27, which ties video and audio input 12 to output 5, RGBHV input 10 to output 9, video input 3 to output 2, and audio input 3 to output 8.
See notes.
Outputs 3, 4, 5, and 6 are assigned to room 8.
Outputs 1, 2, 8, and 9 are assigned to room 3, which named “Class 1”. Command character is a period.

Command/response table for SIS commands (continued)

Command

ASCII command

Response

Additional

 

(host to switcher)

(switcher to host)

description

Save, recall, and directly write presets

NIf you try to recall a preset that is not saved, the matrix switcher responds with the error code E11.

If a room is not defined (does not exist in the switcher), the matrix switcher responds with the error code E21.

The following characters are invalid in preset names: + - , ` @ = [ ] { } ‘ “ ; : \ and ?.

Save current configuration

X1!

Spr

X1!]

Command character is a

as a global preset

,

 

 

comma.

 

 

 

 

Example:

9,

Spr9]

Save current ties as preset 9.

Recall a global preset

X1!

Rpr

X1!]

Command character is a

 

.

 

period.

 

 

 

 

 

Example:

5.

Rpr05]

Recall preset 5, which

 

 

 

 

 

becomes the current

 

 

 

 

 

configuration.

Save current ties for a room

X**X1@,

RmmX*•SprX1@]

Command character is a

 

 

 

 

 

comma.

Example:

3*9,

Rmm03Spr09]

Save current ties as preset 9

 

 

 

 

 

for room 3.

Direct write process

NThe direct write of a global preset should always be preceded by a clear global preset ties command of that same preset number, as shown below. In a directly-written preset, each output position’s tied input (or no tied input) remains unchanged unless overwritten or cleared.

If you do not clear the ties in a global preset number before you directly write a global preset to that number, ties that are part of the previous version of the specified preset with the same number can unexpectedly become part of the newly- created preset.

Clear a global preset’s ties

E+X1!P0*!}

SprX1!]

Directly write a global preset

E+X1!PX@*X#!X@*X#%X@*X#$ ... X@*X#&}

 

 

 

 

 

 

 

 

 

SprX1!]

Example:

E+27P0*!}

Spr27]

 

 

 

 

 

 

 

 

 

Esc+27P12*5!10*09%3*2

$

3*8&

 

 

 

 

 

 

 

 

 

 

Spr27]

Write room outputs

EX*,Y!,Y@, ... Y/MR}

NEach Y` is an output.

A room can contain a maximum of 16 outputs.

An output can belong to only one room.

The maximum number of rooms (X*) is 10.

Example:E8,3,04,5,6MR}

Read room outputs

EX*MR}

 

E3MR}

MprX*,Y!,Y@, ... Y/]

Mpr8,03,04,05,06]

X2#,Y!,Y@, ... Y/]

Class 1,01,02,08,09]

Recall room preset

X**X1@.

RmmX*•RprX1@]

MVX Plus 128 VGA Matrix Switchers • Programmer’s Guide 4-11

Page 81
Image 81
Extron electronic MVX PLUS 128 Command/response table for SIS commands continued, Save, recall, and directly write presets