Fluke 196, 199, 192 Triggering on External Waveforms, Select 1.2V under the Ext Level, Label

Models: 192 196 199

1 116
Download 116 pages 43.11 Kb
Page 58
Image 58

Fluke 192/196/199

Users Manual

Triggering on External Waveforms

Use external triggering when you want to display waveforms on inputs A and B while triggering on a third signal. You can choose external triggering with automatic triggering or with edge triggering.

1Supply a signal to the red and black 4-mm banana jack inputs. See Figure 29.

In this example you continue from the Trigger on Edges example. To choose the external signal as trigger source, continue as follows:

2

 

 

 

 

Display the TRIGGER (On Edges)

 

 

 

 

 

 

 

 

 

key labels.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Select Ext (external) edge trigger.

Observe that the key labels at the bottom of the screen have been adapted to allow selection of two different external trigger levels: 0.12 V and 1.2 V:

 

 

 

Figure 29. External Triggering

 

 

 

 

 

 

 

4

 

 

 

 

 

Select 1.2V under the Ext LEVEL

 

 

 

 

 

 

 

 

 

 

 

label.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

From this point the trigger level is fixed and is compatible with logic signals.

50

Page 58
Image 58
Fluke 196, 199, 192 user manual Triggering on External Waveforms, Select 1.2V under the Ext Level, Label