PD-6DVD Location Recorder (Chapter 3: Names and functions)

16.[HPF] controls

Each control controls the high-pass filter cutoff frequency of the corresponding channel within the range between 50 Hz and 300 Hz.

17.[HPF] switch

Each switch selects the high-pass filter response of the corresponding channel from among “OFF”, “-6 dB/oct.” and “-12 dB/oct.”.

18.[LIMITER] switch

Each switch selects the limiter for the corresponding channel active or inactive.

The limiter parameters can be set using the “Limiter parameter” menu in the

Setup mode (see “Chapter 7: Setup mode” on page 98).

19.[STOP] key/indicator (green)

Stops the recorder, as well as stops the disk rotation. This key is also used to exit a menu operation (of the Setup mode, Utility mode, etc).

<Note>

While operating the PD-6 with the battery, we recommend using the [STOP] key to stop playback rather than using the [PAUSE] key. Because using the [STOP] key stops the disk rotation, which saves battery power.

By pressing the [REW] or [F FWD] key while holding down the [STOP] key, the following operation is possible.

[STOP] + [REW]

Locates to the beginning (ABS 0) of the current file.

 

 

[STOP] + [F FWD]

Locates to the recording end (REC END) of the current file.

 

 

20.[PLAY] key/indicator (green)

Starts playback.

21.[F FWD] key/indicator (green)

Pressing this key while stopped fast-forwards the recorder at maximum 30 x speed.

Pressing this key during playback fast-forwards with sound (cues forwards) at 2 x speed.

Pressing this key while holding down the [STOP] key locates the recording end (REC END) of the current file.

22.[REW] key/indicator (green)

Pressing this key while stopped rewinds the recorder at maximum 30 x speed. Pressing this key during playback rewinds with sound (cues backwards) at 2 x speed.

Pressing this key while holding down the [STOP] key locates the beginning (ABS 0) of the current file.

23.[PANEL LOCK] switch

Switches the panel lock function active (LOCKED) or inactive (OFF).

When set it to the “LOCKED” position, the following keys/switch are inactive.

[STOP] key, [PLAY] key, [F FWD] key, [REW] key, [CIRCLE TAKE] key,

[ SKIP/CURSOR

] key, [FILE SEL] key, [LOCATE] key, [POWER] switch

42

Page 44
Image 44
Fostex PD-6 operation manual HPF controls, HPF switch, Limiter switch, Stop key/indicator green, Play key/indicator green