PD-6DVD Location Recorder (Chapter 7: Setup mode)

<Disk warning>

Option

Comment

 

 

Off

When the remaining recording time of a disk gets under the specified time,

the error tone is not generated.

 

 

 

 

When the remaining recording time of a disk gets under the specified time,

1 to 9 minutes

the error tone is generated. (default setting is 3 minutes)

 

The time can be set in 1 minute steps.

 

 

Battery warning setting (BATT warning)

The “BATT warning” menu sets the threshold of the battery power voltage for automatically ending recording or playback, releasing the disk lock or generating the error tone while the PD-6 is running with the internal battery.

To generate the error tone when the battery power voltage drops below the threshold, the “BATT warning” item in the “Error tone” menu must be set to “On”.

With the “BATT warning” menu, you can set the threshold between 10.5 V and 13.0 V.

flashing

Option

Comment

 

 

10.5 V to 13.0 V

You can set the voltage in 0.5 V steps.

The following settings are recommended depending on the battery used.

(default: 10.5 V)

10.5 V: When a NiCd battery is used.

 

 

12.5 V: When a Lithium ion battery is used.

 

 

<Note>

If the actual voltage lowers the voltage set by the “BATT warning” item for more then one minute, the recorder automatically stops recording or playback, and releases the disk lock.

Speaker mute on/off setting (Speaker mute)

The “Speaker mute” menu selects whether muting the internal monitor speaker or not.

With the “BATT warning” menu, you can select “On” or “Off” for the monitor speaker mute.

flashing

Option

Comment

Off (default)

The monitor speaker is not muted.

On

The monitor speaker is muted except during playback.