Motorized Faders

If you have set the Program Change/Tx parameter to On, the VM200 transmits a Program Change message each time you recall a scene. (The Program Change/Tx parameter appears on the Setup: MIDI 1:MIDI TX&RX function page. See “Program Change Messages” on page 177 for more information.) Using this capability, you can recall programs on other MIDI equipment, such as a tone program on a syn- thesizer. You can record transmission of Program Change messages from the VM200 to a MIDI sequencer to later automate mix scene changes. Refer to the “Using Program Change Messages to Recall Scenes” on page 180 for more information.

Motorized Faders

In order for the faders to move to their new positions automatically when you change scenes, the Motor parameter must be turned on. The Motor parameter appears on the SETUP: SYSTEM 1:CLOCK/MON func- tion page.

Follow the steps below to turn the motorized faders on or off.

1.Press the [SYSTEM] key once to display the 1: CLOCK/MON func- tion page.

turning motorized faders on and off

2.Rotate the EQ/LO Q rotary control to turn the Motor parame- ter on or off.

The default setting is “OFF.”

Warning: Do not force the automated faders or you may damage the VM200.

Note: If the Motor parameter is turned on, the fader will move suddenly and automatically when a new scene is recalled or the Fader Mode is changed.

VM200 User’s Guide

153

Page 153
Image 153
Fostex VM200 manual Motorized Faders