Examples: Using Control Change Messages

Examples: Using Control Change Messages

The following figures illustrate typical ways in which to utilize MIDI Control Change messages with the VM200.

The following example assumes you are using the Preset Control Change Table (which appears on function page 5:CTL TABLE2) and that an assignable MIDI controller on the MIDI keyboard has been assigned Control Change 83.

When you adjust the controller, Control Change 83 will be transmit- ted to the VM200, which will then adjust the effect send 2 level for input channel 2.

MIDI IN

MIDI OUT

MIDI keyboard

In the following example, input channel 5 fader movements are recorded in real time to a MIDI sequencer using Control Change 5. During playback, the sequencer transmits Control Change 5 back to the VM200 and fader 5 moves accordingly, due to preset assignment.

MIDI IN

MIDI OUT

MIDI IN

MIDI OUT

MIDI sequencer

You can also connect two VM200s via MIDI to enable you to control the second VM200 from the first. For example, you could move the Master Fader on the first VM200, causing the second VM200 to oper- ate its Master Fader as well.

VM200 UserÕs Guide

187

Page 187
Image 187