CONTINUED FROM

PRECEEDING PAGE

Is the right HI LED lit (for split vat

units, both HI LEDs lit)?

YES

Is 24VAC present on the Latching Contactor AND does the contactor close?

YES

As HEATING MODE indicator lights, does the right HT LED light (both HT LEDs for split-vat units)?

YES

Is 24 VAC present on the

Heating Contactor and does the

Heating Contactor close?

YES

Continued on

next page

NO

NO

NO

NO

Probable causes are:

1. Open high-limit

2. Open/defective drain-valve microswitch

3.Broken or improper wire connection

4.Defective latching relay

Probable causes are:

1.Defective latching relay

2.Defective latching contactor

3.Defective interface board

4.Broken or improper wire connection

Probable causes are:

1.Broken or improper wire connection

2.Defective interface board

Probable causes are:

1.Defective interface board 2. Broken or defective wiring

connection

3.Defective heating contactor

6-4

Page 44
Image 44
Frymaster H14 Series service manual From Preceeding