CHAPTER 7: SERVICE PROCEDURES
Before performing any maintenance on your Frymaster fryer, you must disconnect the electrical power supply.
When electrical wires are disconnected, it is recommended that they be marked in such a way to facilitate
7-1: REPLACE CONTROLLER
1.Unscrew and remove two control panel screws.
2.Control panel is hinged at the bottom and will swing open from the top.
3.Unplug wiring harness at plug on back of controller.
4.Control panel including controller can be removed by lifting the assembly from the hinged slots in the control panel frame.
5.Reverse procedures to install new controller.