7-8: REPLACE CONTACTOR

1.Perform Procedure 7-4, Replace Temperature Probe, Steps 1-3.

2.Remove the screws securing the bottom and center rear access covers. Set the screws and covers aside.

3.If present, remove the screws securing the wiring covers to the front of the contactor box (optional on old-style contactor boxes). Set the screws and covers aside.

4.Disconnect the wire harnesses from the front and rear of the contactor box.

Screws securing wire cover to contactor box (optional

on old-style contactor boxes)

5.Remove the screws securing the contactor box to the bottom frame of the fryer.

6.Pull the contactor box through the access opening in the rear of the fryer.

7.Remove the screws securing the contactor box cover. Set the screws and covers aside.

Location of screws securing contactor box to bottom frame

8.Remove all wiring connected to the contactor terminals inside the contactor box. Mark each wire for re-assembly.

Mark each wire for re-assembly, then remove all wiring connected to the contactor(s) to be replaced.

7-11

Page 61
Image 61
Frymaster H14 Series service manual Replace Contactor