Frymaster H14 Series FootPrint III Wiring Diagram, BUILT-IN FILTER SYSTEM SERVICE PROCEDURES cont

Models: H14 Series

1 110
Download 110 pages 58.94 Kb
Page 65
Image 65
FootPrint III Wiring Diagram

7-10: BUILT-IN FILTER SYSTEM SERVICE PROCEDURES (cont.)

Line

7-15 VAC

All Heater Tapes (Original and

Redesigned Models)

(Heater Tapes have been removed from return lines in Redesigned Models)

24

VAC

Solenoids

(Redesigned Models Only)

Micro-switches

Pump Relay

Coil

Pump Motor

M

Pump Motor Switch

FootPrint III Wiring Diagram

Operation of the redesigned FP-III system is the same as for the original design.

ORIGINAL VS REDESIGNED FP-III FILTRATION SYSTEM

Original System

Redesigned System

 

Return lines and manifolds wrapped with silicone

No heater strips or aluminum tape on return

strip heaters and aluminum tape.

lines.

 

Filter base assembly connected to unit with a

Non-heated Teflon hose with a swivel joint

black, heated return hose beneath the filter.

connects the filter base assembly to the unit

 

above the filter.

 

Filter base assembly equipped with swivel

Filter base assembly has no casters.

 

casters.

 

 

Operator-removable filter base assembly. (Filter

Filter base assembly is not removable except by

base assembly stoplocks in cabinet can be

a qualified service technician.

(Filter base

rotated to remove tray.)

assembly stoplocks fitted with a screw and nut to

 

prevent filter removal.)

 

Oil/shortening remains in return lines when filter

Oil/shortening gravity-drains back to the filter pan

system is turned off.

when filter system is turned off, leaving no oil or

 

shortening in return lines.

 

Return drain-manifolds are constructed with pipe

Return drain manifolds are one-piece with an in-

nipples, elbows and other plumbing components.

line solenoid valve to facilitate gravity drain-back

 

to filter pan.

 

7-15

Page 65
Image 65
Frymaster H14 Series service manual FootPrint III Wiring Diagram, BUILT-IN FILTER SYSTEM SERVICE PROCEDURES cont, 7-15