6.2.2 Troubleshooting Fryers Equipped with Analog Controllers

Fryer Off

CONTROLLER

PANEL OPEN

INTERFACE

BOARD VISIBLE

Press the ON/

OFF switch (OFF

displayed in

window).

Is the CMP LED in the top center of the interface board illuminated?

NO

Probable causes are:

1.No power applied to the fryer power cord

2.Defective 12-volt transformer

3.Defective interface board

4.Broken or improper wire connection

YES

Is the 24V LED on the

NO

interface board

 

illuminated?

 

 

YES

 

 

 

Is the AL LED illuminated?

NO

 

Probable causes are:

1. Defective 24-volt transformer

2.Defective interface board

3.Broken or improper wire connection

Probable causes are:

1. Defective interface board

YES

Condition normal.

6-6

Page 46
Image 46
Frymaster H14 Series service manual Is the AL LED illuminated?