7-11: ELECTRIC INTERFACE BOARD DIAGNOSTIC CHART

The following diagram and charts provide ten quick system checks that can be performed using only a multimeter.

 

 

 

3

2

1

 

 

 

 

 

 

6

5

4

 

 

 

 

 

 

9

8

7

 

 

 

 

 

 

12

11

10

 

 

 

 

 

 

15

14

13

 

 

 

K1

 

 

K2

K3

K4

 

 

10

7

4

1

 

10

7

4

1

11

8

5

2

 

11

8

5

2

12

9

6

3

 

12

9

6

3

Note: The sealed relays are not replaceable. If a relay fails the interface board must be replaced.

 

Diagnostic LED Legend

CMP

indicates power from 12V transformer

24

indicates power from 24V transformer

HI

(RH) indicates output (closed) from right Latch

 

relay

HI

(LH) indicates output (closed) from left Latch relay

HT

(RH) indicates output from right Heat relay

HT

(LH) indicates output from left Heat relay

AL

(RH) indicates output (open) from right Latch relay

AL

(LH) indicates output (open) from left Latch relay

Meter Setting

Test

Pin

 

Pin

 

Results

12 VAC Power

50 VAC Scale

1 of J2

 

3 of J2

12-16 VAC

24 VAC Power

50 VAC Scale

2 of J2

 

Chassis

24-30

VAC

*Probe Resistance (RH)

R X 1000 OHMS

11 of J2

 

12 of J2

See Chart

*Probe Resistance (LH)

R X 1000 OHMS

3 of J1

 

2 of J1

See Chart

Hi-Limit Continuity (RH)

R X 1 OHMS

7 of J2

 

4 of J2

0 - OHMS

Hi-Limit Continuity (LH)

R X 1 OHMS

4 of J1

 

7 of J1

0 - OHMS

Latch Contactor Coil (RH)

R X 1 OHMS

8 of J2

 

Chassis

3-10 OHMS

Latch Contactor Coil (LH)

R X 1 OHMS

5 of J1

 

Chassis

3-10 OHMS

Heat Contactor Coil (RH)

R X 1 OHMS

9 of J2

 

Chassis

18-25

OHMS

Heat Contactor Coil (LH)

R X 1 OHMS

6 of J1

 

Chassis

18-25

OHMS

*Disconnect 15-Pin harness from the computer/controller before testing the probe circuit.

7-16

Page 66
Image 66
Frymaster H14 Series service manual Electric Interface Board Diagnostic Chart, Diagnostic LED Legend