6.2.1 Troubleshooting Fryers Equipped with M100B Computers

Fryer Off

COMPUTER PANEL

OPEN

INTERFACE

BOARD VISIBLE

Press the ON/

OFF switch (OFF

displayed in

window).

Is the CMP LED in the top center of the interface board illuminated?

NO

Probable causes are:

1.No power applied to the fryer power cord

2.Defective 12-volt transformer

3.Defective interface board

4.Broken or improper wire connection

YES

Is the 24V LED on the

NO

interface board

 

illuminated?

 

 

YES

 

 

 

Probable causes are:

1. Defective 24-volt transformer

2.Defective interface board

3.Broken or improper wire connection

Is the AL LED illuminated?

NO

Probable causes are:

1. Defective interface board

YES

Condition normal.

6-2

Page 42
Image 42