CHAPTER 6 DETAILED RULES FOR EXECUTION INSTRUCTIONS

6.64ORW (OR Word Data of Accumulator and Temporary Accumulator to Accumulator)

Carry out the logical OR on the word data of A and T for every bit and return the results to A.

ORW (OR Word Data of Accumulator and Temporary Accumulator to Accumulator)

Operation

(A) (A) (T) (word logical OR)

Assembler format

ORW A

Condition code (CCR)

N

Z

V

C

 

 

 

 

+

+

R

-

 

 

 

 

+: Changed by executing instruction

-: Not changed

R: Set to 0 by executing instruction

N:Set to 1 if the MSB of A is 1 as the result of operation and set to 0 in other cases.

Z:Set to 1 if the result of operation is 0000H and set to 0 in other cases.

V:Always set to 0

C:Not changed

Number of execution cycle: 1

Byte count: 1

OP code: 73

174

Page 186
Image 186
Fujitsu F2MC-8FX manual ORW a