CHAPTER 6 DETAILED RULES FOR EXECUTION INSTRUCTIONS

6.56 MOVW (MOVE Immediate Word Data to Index Register)

Transfer word immediate data to IX.

MOVW (MOVE Immediate Word Data to Index Register)

Operation

(IX) d16 (Word transfer)

Assembler format

MOVW IX, #d16

Condition code (CCR)

N

Z

V

C

 

 

 

 

-

-

-

-

 

 

 

 

+: Changed by executing instruction

-: Not changed

N:Not changed

Z:Not changed

V:Not changed

C:Not changed

Number of execution cycles: 3

Byte count: 3

OP code: E6