Fujitsu FMW4503TS128A01 Serial/Parallel Port Configuration Submenu Options, 3F8 3FF, 2E8 2EF

Models: FMW4503TS128A01

1 110
Download 110 pages 47.55 Kb
Page 21
Image 21

Serial/Parallel Port Configuration Submenu Options

Configuration options for the Serial/Parallel Port Configuration submenu are given in Table 3-4.Note that some peripheral interfaces are only available when using a device attached to the system interface port such as the mini-dock.

Table 3-4. Serial/Parallel Port Configurations Submenu Options

Option

Settings

Description

 

 

 

Serial Port

Disabled

Determines whether the serial port is active and the

 

Enabled

method used to configure the serial port.

 

Auto

 

 

 

Select [Auto] to allow the BIOS or operating system

 

 

to configure the port automatically.

 

 

Select [Enabled] to configure the Base I/O Address

 

 

and Interrupt options manually in BIOS setup.

 

 

Select [Disabled] to turn serial port A off.

 

 

 

I/O Address

3F8 - 3FF

Determines the base I/O address used for the serial

 

2F8 - 2FF

port. The Serial Port option must be set to [Enabled]

 

3E8 - 3EF

before this setting can be changed.

 

2E8 - 2EF

 

 

 

 

Interrupt

IRQ 3

Determines the interrupt request level used for the

 

IRQ 4

serial port. The Serial Port option must be set to

 

 

[Enabled] before this setting can be changed.

 

 

 

Infrared Port

Disabled

Determines whether the infrared port is active and

 

Enabled

the method used to configure the infrared port.

 

Auto

 

 

 

Select [Auto] to allow the BIOS or operating system

 

 

to configure the port automatically.

 

 

Select [Enabled] to configure the I/O Address and

 

 

Interrupt options manually in BIOS setup.

 

 

Select [Disabled] to turn off the infrared port.

 

 

 

Mode

IrDA

Determines which physical interface the infrared port

 

FIR

is assigned to. Select IrDA to use the IrDA port in

 

 

Standard IR (SIR) mode (115 Kbps). Select FIR to

 

 

use the IrDA port in Fast IR mode (4 Mbps).

 

 

 

I/O Address

3F8 - 3FF

Determines the base I/O address used for the

 

2F8 - 2FF

infrared port. The Infrared Port option must be set to

 

3E8 - 3EF

[Enabled] before this setting can be changed.

 

2E8 - 2EF

 

 

 

 

Interrupt

IRQ 3

Determines the interrupt request level used for the

 

IRQ 4

infrared port. The Infrared Port option must be set to

 

 

[Enabled] before this setting can be changed.

 

 

 

I/O Address

100 - 107

Determines the base I/O address for the infrared

 

108 - 10F

port. This option is only selectable when the Infrared

 

110 - 117

Port Mode setting is FIR.

 

118 - 11F

 

 

 

 

BIOS Setup

11

Page 21
Image 21
Fujitsu FMW4503TS128A01 manual Serial/Parallel Port Configuration Submenu Options, 3F8 3FF, 2E8 2EF, 118 11F