Command

 

Specification

Default

 

 

 

 

 

 

/N

 

0

Normal speed-buffered mode.

 

 

 

 

 

 

 

 

 

1

Direct mode (if parallel I/F is selected, same as /NO).

 

 

 

 

 

 

 

 

 

2

MNP reliable mode (MNP -> disconnect)

 

 

 

 

 

 

 

 

 

3

Auto-reliable mode (LAPM -> MNP -> NORMAL -> disconnect).

3

 

 

 

Same as /N5.

 

 

 

 

 

 

 

 

 

4

LAPM-reliable mode (LAPM -> disconnect)

 

 

 

 

 

 

 

 

 

5

Auto-reliable mode (LAPM -> MNP -> NORMAL -> disconnect).

 

 

 

 

Same as /N3.

 

 

 

 

 

 

 

/V

 

0

Disable protocol result code appended to DCE speed.

 

 

 

 

 

 

 

 

 

1

Enable protocol result code appended to DCE speed.

3

 

 

 

 

 

 

 

 

2

Same as /V1.

 

 

 

 

 

 

 

/X

 

0

Do not pass XON/XOFF flow control characters.

3

 

 

 

 

 

 

 

 

1

Pass XON/XOFF flow control characters.

 

 

 

 

 

 

-V90=<n>

=0

Disable V.90

 

 

 

 

 

 

 

 

 

 

=1

Enable V.90 Auto Rate

3

 

 

 

 

 

 

 

 

 

=2

Attempt to connect at 28000 bit/s

 

 

 

 

 

 

 

 

 

 

=3

Attempt to connect at 29333 bit/s

 

 

 

 

 

 

 

 

 

 

=4

Attempt to connect at 30666 bit/s

 

 

 

 

 

 

 

 

 

 

=5

Attempt to connect at 32000 bit/s

 

 

 

 

 

 

 

 

 

 

=6

Attempt to connect at 33333 bit/s

 

 

 

 

 

 

 

 

 

 

=7

Attempt to connect at 34666 bit/s

 

 

 

 

 

 

 

 

 

 

=8

Attempt to connect at 36000 bit/s

 

 

 

 

 

 

 

 

 

 

=9

Attempt to connect at 37333 bit/s

 

 

 

 

 

 

 

 

 

 

=10

Attempt to connect at 38666 bit/s

 

 

 

 

 

 

 

 

 

 

=11

Attempt to connect at 40000 bit/s

 

 

 

 

 

 

 

 

 

 

=12

Attempt to connect at 41333 bit/s

 

 

 

 

 

 

 

 

 

 

=13

Attempt to connect at 42666 bit/s

 

 

 

 

 

 

 

 

 

 

=14

Attempt to connect at 44000 bit/s

 

 

 

 

 

 

 

 

 

 

=15

Attempt to connect at 45333 bit/s

 

 

 

 

 

 

 

 

 

 

=16

Attempt to connect at 46666 bit/s

 

 

 

 

 

 

 

 

 

 

=17

Attempt to connect at 48000 bit/s

 

 

 

 

 

 

 

 

 

 

=18

Attempt to connect at 49333 bit/s

 

 

 

 

 

 

 

 

 

 

=19

Attempt to connect at 50666 bit/s

 

 

 

 

 

 

 

 

 

 

=20

Attempt to connect at 52000 bit/s

 

 

 

 

 

 

 

AT Commands Table