 Setting hopper time
Mode 1
Mode 2
Mode 2
Mode 1
Mode 2
Mode 1

 Setting heater control Setting hopper time

When you set the picking time, you must set as follows:

1 In Screen 2, press 16 times (17 times for M3099GX/GH) to display HOPPER TIMER screen. <Screen 36>

2 Press Manual background to display Screen 37. (The default setting is 7 seconds.)

3 In Screen 37, press Manual background until the digit you want to change blinks. Then press Manual background until the value you want to select appears. (The selectable range is from 0 to 30 seconds in steps of 1 second.)

4 Press Mode 1 and Manual background at the same time to display Screen 36. The settings are stored in

EEPROM.

5When you close the setup mode, press

Stop .

<Screen 36>

< < S E T U P M O D E > >

H O P P E R T I ME R

<Screen 37>

H O P P E R T I ME R

X X S

(Blinking)

Manual background Setting heater control

When you set the heater control, you must set as follows:

1 In Screen 2, press Manual background 17 times (18 times for M3099GX/GH) to go to the HEATER CONTROL screen. <Screen 38>

2

Press Mode 2 to display Screen 39.

If “ON”

<Screen 38>

 

 

 

 

is displayed, the heater control will be done.

< < S E T U P M O D E > >

 

If “OFF” is displayed, warming-up will finish

 

H E A T E R C O N T R O L

 

within 30 seconds, if necessary. When the

 

heater is broken, please set “OFF”. Each

 

 

 

 

time Mode 1 is pressed, “ON” and “OFF”

 

 

 

 

appear alternately. The setting is stored in

<Screen 39>

 

EEPROM automatically.

 

3

Press Mode 2 to display Screen 38. When

H E A T E R C O N T R O L

 

 

 

 

you close the setup mode, press

Stop .

 

O N

 

 

 

 

 

 

 

Manual background 7-14