4.Delete the system board.

Execute the deleteboard(8) command to delete the system board.

XSCF> deleteboard -c disconnect 01-0

5.Check the status of the system board.

Execute the showboards(8) command to display system board information, and then check the status of the system board.

XSCF> showboards 01-0

 

XSB DID(LSB) Assignment Pwr Conn Conf Test

Fault

-----------------------------------------------------------------

01-0 00(01)

Assigned

y

n

n

Passed Normal

6.Physically replace the system board.

Execute the replacefru(8) command, then follow the displayed instructions to replace the system board per the Hot Replacement procedure. For information about Hot Replacement, see the SPARC Enterprise M8000/M9000 Servers Service Manual.

XSCF> replacefru

7.Check the status of the replaced system board.

Execute the showboards(8) command to display system board information, and then check the status of all related system boards and confirm their registration in the DCL.

If necessary to change the system board configuration (e.g., number of divisions), do so by using the setupfru(8) command. If the system board is not registered in the DCL, register it in the DCL for the target domain by using the setdcl(8) command.

XSCF> showboards 01-0

 

XSB DID(LSB) Assignment Pwr Conn Conf Test

Fault

-----------------------------------------------------------------

01-0 00(01)

Assigned

y

n

n

Passed Normal

4-14SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007