[Remedy] Power off the domain by specifying "-c reserve".XSB#XX-X detected timeout by DR self test.

[Explanation] The timeout occurred during DR processing because the hardware diagnosis did not complete. There is something wrong with the hardware.

[Remedy] Find out the cause of the DR failure referring monitoring message and errorlog. Replace the failure component.

XSB#XX encountered a hardware error. See error log for details.

[Explanation] An error occurred during hardware diagnosis. There is something wrong with the hardware.

[Remedy] Find out the cause of the DR failure referring monitoring message and errorlog. Replace the failure component.

IP address of DSCP path is not specified.

[Explanation] The DR processing cannot communicate the domain because DSCP IP Address is not set up.

[Remedy] Register the DSCP IP Address.

An internal error has occurred. This may have been caused by a DR library error.

[Explanation] The DR processing cannot be failed on the domain OS. The error occurred at the DR library.

[Remedy] Find out the cause of the DR failure referring monitoring message and errorlog. Confirm the patch applying status and the XCP version.

DR failed. Domain (DomainID X) cannot communicate via DSCP path.

[Explanation] DR processing cannot communicate with the domain. The reasons are that domain is powered off, the DSCP setting is wrong or the error occurs at the DSCP path.

[Remedy] Confirm the domain powered off, DSCP setting, DSCP error with monitoring message and errorlog.

XSB#03-0 could not be unconfigured from DomainID 1 due to operating system error, or XSB#03-0 could not be configured into DomainID 0 due to operating system error.

[Explanation] An error occurred in DR library of domain OS at DR process. The error occurred at configuration management of domain OS.

A-30SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007