[Remedy] Find out the cause of the DR failure referring monitoring message and errorlog. Confirm the patch applying status and the XCP version
DR failed. Domain (DomainID X) cannot communicate via DSCP path.
[Explanation] DR processing cannot communicate with the domain. The reasons are that domain is powered off, the DSCP setting is wrong or the error occurs at the DSCP path.
[Remedy] Confirm the domain powered off, DSCP setting, DSCP error with monitoring message and errorlog.
[Explanation] An error occurred from DR library of domain OS at DR process. The error occurred at configuration management of domain OS.
[Remedy] Find out the cause of the DR failure referring monitoring message and console message. Try again after taking out cause.
Invalid parameter.
[Explanation] There is an error in the specified argument or operand.
[Remedy] Confirm the specified argument or operand and execute the command once again.
Permission denied.
[Explanation] Do not have privilege.
[Remedy] Confirm the user privilege and the command privilege. In the case of
The current configuration does not support this operation.
[Explanation] Cannot execute the command in the current configuration, or it is not supported.
[Remedy] Confirm the current hardware configuration and support status.
A hardware error occurred. Please check the error log for details.
[Explanation] Hardware error occurred. Please confirm monitoring message and the error log.
[Remedy] Find out the cause of the DR failure referring monitoring message and error log. Replace the failure component.
Appendix A Message Meaning and Handling