An internal error has occurred. Please contact your system administrator.

[Explanation] DR failed. There is a possibility that DR failed because of an internal error in XSCF.

[Remedy] Find out the cause of the DR failure referring monitoring message and error log. Please also confirm the XCP version.

Timeout detected during self-test of XSB#XX-X.

[Explanation] Because the hardware diagnosis in DR did not complete, a timeout occurred. There is a possibility that a hardware error occurred.

[Remedy] Find out the cause of the DR failure referring monitoring message and error log. Replace the failure component.

A.2.2 deleteboard

XSB#XX-X will be unassigned from domain immediately. Continue? [yn]:

[Explanation] Confirming whether DR operation is going to be executed or not. Input "y" to execute it and "n" to stop it.

XSB#XX-X will be unconfigured from domain immediately.Continue? [yn]:

[Explanation] Confirming whether DR operation is going to be executed or not. Input "y" to execute it and "n" to stop it.

XSB#XX-X will be unassigned from domain after the domain restars. Continue? [yn]:

[Explanation] Confirming whether DR operation is going to be executed or not. Input "y" to execute it and "n" to stop it.

DR operation canceled by operator.

[Explanation] DR operation canceled by operator

XSB#XX-X is not installed.

[Explanation] System board (XSB#XX-X) is not installed.

[Remedy] Specify the wrong XSB. Confirm the XSB by showboards(8).

XSB#XX-X is currently unavailable for DR. Try again later.

A-26SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007