4.2Example: Adding a System Board

This section provides an example of the DR operation to add a system board to a domain. In the example, a procedure conforming to section <LinkColor>4.1.1, "Flow: Adding a System Board.", is used, and the system board shown in the figure is added by using the XSCF shell.

FIGURE 4-5Example: Adding a System Board

Domain#0

 

 

Domain#0

 

XSB#00-0

XSB#01-0

Add

XSB#00-0

XSB#01-0

 

 

1.Login to XSCF.2.Check the status of the domain.

Execute the showdcl(8) command to display domain information, and then check the operation status of the domain. Based on the operation status of the domain, determine whether to perform the DR operation or change the domain configuration.

XSCF> showdcl -d 0

DID LSB XSB Status

00Running

0000-0

0101-0

3.Check the status of the system board to be added.

Execute the showboards(8) command to display system board information, and then check the status of the system board to be added and confirm its registration in the DCL.

4-6SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User’s Guide • September 2007