[Remedy] Repeat the action. If the problem still exists, please contact customer service.
[Output] Console and Standard Output
dr_move_memory: failed to quiesce OS for[Remedy] Repeat the action. If this error message appears again, please contact customer service.
[Output] Console and Standard Output
No available memory target: dr@0:SBX::memory[Explanation] The system board cannot be detached because it contains kernel memory and there is no available target memory board.
[Remedy] Add new system board and then try the detach operation again.[Output] Console and Standard Output
Unsafe driver present: <driver namemajor #> ...[Explanation] DR driver found DR unsafe drivers in the system. [Remedy] Unload the unsafe drivers and try the DR operation again. [Output] Console and Standard Output
Device failed to resume: <driver namemajor #> ...[Explanation] Devices on the list failed to resume[Remedy] Please contact customer service.
[Output] Console and Standard Output
Device failed to suspend: <driver namemajor #> ...[Explanation] Devices on the list failed to suspend[Remedy] Please contact customer service.
[Output] Console and Standard Output
Operation not supported: ERROR[Explanation] Invalid operation.[Remedy] Repeat the action. If this error message appears again, please contact customer service.