CONTROLLER

 

 

R

Σ

X

DIGITAL

Y

DAC

V

 

 

FILTER

ZOH

AMP

 

 

 

 

 

 

 

 

C

 

 

 

 

ENCODER

Figure 10.4 - Functional Elements of a Motion Control System

Motor-Amplifier

The motor amplifier may be configured in three modes:

1.Voltage Drive

2.Current Drive

3.Velocity Loop

The operation and modeling in the three modes is as follows:

Voltage Drive

E

MOTOR

P

The amplifier is a voltage source with a gain of Kv [V/V]. The transfer function relating the input voltage, V, to the motor position, P, is

PV = KV [Kt S(STm + 1)(STe + 1)]

where

T

= RJ

K 2

[s]

m

 

t

 

and

 

 

 

Te

= L R

 

[s]

and the motor parameters and units are

Kt

R

J

L

Torque constant [Nm/A]

Armature Resistance Ω

Combined inertia of motor and load [kg.m2] Armature Inductance [H]

When the motor parameters are given in English units, it is necessary to convert the quantities to MKS units. For example, consider a motor with the parameters:

Kt = 14.16 oz - in/A = 0.1 Nm/A R = 2 Ω

J= 0.0283 oz-in-s2= 2.10-4kg . m2 L = 0.004H