05 specifies bit 0 is active for A axis and bit 2 is active for C axis (20 + 22=5) 03 E8 represents 1000

FE OC represents -500

Example

The command ST XYZS would be A1 00 01 07

where A1 is the command number for ST 00 specifies 0 data fields

01 specifies stop the coordinated axes S

07 specifies stop X (bit 0), Y (bit 1) and Z (bit 2) 20+21+23 =7

Binary command table

Command

No.

Command

No.

Command

No.

 

 

 

 

 

 

 

 

 

 

 

 

reserved

80

reserved

ab

reserved

d6

 

 

 

 

 

 

KP

81

reserved

ac

reserved

d7

KI

82

reserved

ad

RP

d8

 

 

 

 

 

 

KD

83

reserved

ae

TP

d9

 

 

 

 

 

 

DV

84

reserved

af

TE

da

 

 

 

 

 

 

AF

85

LM

b0

TD

db

 

 

 

 

 

 

KF

86

LI

b1

TV

dc

 

 

 

 

 

 

PL

87

VP

b2

RL

dd

 

 

 

 

 

 

ER

88

CR

a3

TT

de

 

 

 

 

 

 

IL

89

TN

b4

TS

df

TL

8a

LE, VE

b5

TI

e0

 

 

 

 

 

 

MT

8b

VT

b6

SC

e1

 

 

 

 

 

 

CE

8c

VA

b7

reserved

e2

 

 

 

 

 

 

OE

8d

VD

b8

reserved

e3

 

 

 

 

 

 

FL

8e

VS

b9

reserved

e4

 

 

 

 

 

 

BL

8f

VR

ba

TM

e5

 

 

 

 

 

 

AC

90

reserved

bb

CN

e6

DC

91

reserved

bc

LZ

e7

 

 

 

 

 

 

SP

92

CM

bd

OP

e8

 

 

 

 

 

 

IT

93

CD

be

OB

e9

 

 

 

 

 

 

FA

94

DT

bf

SB

ea

 

 

 

 

 

 

FV

95

ET

c0

CB

eb

 

 

 

 

 

 

GR

96

EM

c1

I I

ec

 

 

 

 

 

 

DP

97

EP

c2

EI

ed

 

 

 

 

 

 

DE

98

EG

c3

AL

ee

 

 

 

 

 

 

 

 

 

 

 

 

Chapter 5 Command Basics • 58

USER MANUAL

Page 58
Image 58
Galil DMC-13X8 user manual Binary command table, Example, Command, Le, Ve