Command Summary - Stepper Motor Operation

COMMAND

DE

DP

IT

KS

MT

RP

TD

TP

DESCRIPTION

Define Encoder Position (When using an encoder) Define Reference Position and Step Count Register Motion Profile Smoothing - Independent Time Constant Stepper Motor Smoothing

Motor Type (2,-2,2.5 or -2.5 for stepper motors) Report Commanded Position

Report number of step pulses generated by controller Tell Position of Encoder

Operand Summary - Stepper Motor Operation

OPERAND

_DEx

_DPx

_ITx

_KSx

_MTx

_RPx

_TDx

_TPx

DESCRIPTION

Contains the value of the step count register for the ‘x’ axis Contains the value of the main encoder for the ‘x’ axis Contains the value of the Independent Time constant for the 'x' axis

Contains the value of the Stepper Motor Smoothing Constant for the 'x' axis Contains the motor type value for the 'x' axis

Contains the commanded position generated by the profiler for the ‘x’ axis Contains the value of the step count register for the ‘x’ axis

Contains the value of the main encoder for the ‘x’ axis

Stepper Position Maintenance Mode (SPM)

The Galil controller can be set into the Stepper Position Maintenance (SPM) mode to handle the event of stepper motor position error. The mode looks at position feedback from the main encoder and compares it to the commanded step pulses. The position information is used to determine if there is any significant difference between the commanded and the actual motor positions. If such error is detected, it is updated into a command value for operator use. In addition, the SPM mode can be used as a method to correct for friction at the end of a microstepping move. This capability provides closed- loop control at the application program level. SPM mode can be used with Galil and non-Galil step drives.

SPM mode is configured, executed, and managed with seven commands. This mode also utilizes the #POSERR automatic subroutine allowing for automatic user-defined handling of an error event.

Internal Controller Commands (user can query):

QS

Error Magnitude (pulses)

User Configurable Commands (user can query & change):

OE

Profiler Off-On Error

USER MANUAL

Chapter 6 Programming Motion • 93

Page 93
Image 93