TECHNICAL TROUBLESHOOTING continued

Controller Display is BLANK, Main Power (ON / OFF) light or indicator is LIT

Probable diagnosis

 

 

Check for loose or

Check for 120 VAC at terminal

YES

disconnected black wires on

marked “LIM” & “N”

coil of contactor and black

 

 

wires going to 24VAC

 

 

transformers.

NO

 

 

Trace circuit for terminal

 

 

marked “LIM” brown wire to

 

Repair Open or damaged

back of unit and into molex

YES

wire

plug. Check for open

 

 

 

circuit.

 

 

NO

Check for continuity in rear

 

 

of unit at molex plugs at

YES

 

brown wires marked “50”

Check opposite side

and “51”

 

 

Part # JIBSM08 Rev.6 (08/04/09)

Page 41

Page 41
Image 41
Garland XG24-JIB, XG36-JIB service manual Probable diagnosis