TECHNICAL TROUBLESHOOTING continued

Master Power (ON / OFF) Switch turned ON - Power Light in On - Grill is not heating

Controller display reads “OFF”

NO

High voltage power cord(s) unplugged

NO

High voltage circuit breaker at service panel is OFF or tripped

NO

Check for 120 VAC at terminal block between LIM & NEUT

Test continuity on contactor

coil between LIM & NEUT

NO

YES

YES

YES

YES

YES

Press the MENU SELECT

button.

Reconnect power supply

Reset circuit breaker

Disconnect power supply and perform continuity test on terminals of high limit in upper platen

NO

Replace defective high limit

Replace defective contactor