TECHNICAL TROUBLESHOOTING continued
Master Power (ON / OFF) Switch turned ON - Power Light in On - Grill is not heating
Controller display reads “OFF”
NO
High voltage power cord(s) unplugged
NO
High voltage circuit breaker at service panel is OFF or tripped
NO
Check for 120 VAC at terminal block between LIM & NEUT
Test continuity on contactor
coil between LIM & NEUT
NO
YES
YES
YES
YES
YES
Press the MENU SELECT
button.
Reconnect power supply
Reset circuit breaker
Disconnect power supply and perform continuity test on terminals of high limit in upper platen
NO
Replace defective high limit
Replace defective contactor
Page 42 | Part # JIBSM08 Rev 7 (08/04/09) |