TECHNICAL TROUBLESHOOTING continued

Controller Displays “MOTOR OVER CURRENT” - Platen does not move at all

Check voltage of limit switches. 5.6 VDC when switch is Open, 0 VDC when switches are closed.

NO

Check for 120 volts at the motor speed controller. Pins 3 & 4.

NO

Possible broken connection between the motor speed controller and the terminal block, terminal marked “SW”.

YES

Replace defective Limit

Switch

 

YES

Check for 120 - 140 VDC on

 

Replace defective Motor

pins 1 & 2 or Motor Speed

NO

Speed Controller.

 

Controller.

 

 

 

YES

 

 

 

Check for positive

 

 

 

connection at input leads

 

 

 

of Linear Actuator.

 

 

 

YES

 

 

 

Check for binded actuator by

 

From behind the unit

 

disconnecting the upper

NO

manually raise and lower the

 

mounting pin, and manually

platen by lifting up on the

 

spinning actuator shaft.

 

platen arms.

 

YES

 

YES

 

 

 

 

 

 

Replace worn or damaged

 

Replace defective linear

 

components.

 

 

 

 

actuator.

 

 

Controller Displays “MOTOR OVER CURRENT” - Platen stops and moves to lower limit

Check voltage of upper limit

 

Does Upper Limit

 

 

switches while platen is in the

YES

Switch change states of 5.6

YES

Replace defective Motor

upward movement.

 

VDC to 0 VDC?

 

Speed Controller.

 

 

NO

 

 

 

 

Replace faulty Upper Limit

 

 

 

 

Switch.

 

 