TECHNICAL TROUBLESHOOTING continued

Controller Displays “IGNITION FAILURE” - No flame at all

Do the burners light at all?

NO

Check quick disconnect for improper connection

NO

Check for incoming gas pressure at the main incoming gas manifold

NO

Check main gas manifold shut-o￿ valve, and turn on

YES

YES

YES

YES

Does the ￿ame go out?

Reconnect quick disconnect

on gas supply hose

Turn gas valve ON

Locate gas shut o￿ valve and turn to ON

 

Check for proper gas

 

YES

pressure - Incoming &

 

 

manifold pressure

 

 

 

NO

 

YES

Adjust incoming & burner

 

 

pressure for gas type

Check for proper microamp reading

NO

Check air output from

YESblower. Blower output should be 1”W.C.

NO

NO

See Technical Troubleshooting

“Controller displays Ignition Failure -

Flame does not light at all”.

Check all ￿ame sensor connections for security.

YES

Replace blower

NO

Replace ignitor assy.

Adjust microamps

at plenum box.

 

Controller Displays “IGNITION FAILURE” - Flame does not light at all

Is the blower running?

NO

Check of 120 VAC at blower.

YES

Replace Blower Motor

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

Check for input voltage from

 

 

 

 

 

NO

main controller. ~8.9 VDC at

Check for air pressure

YES

Check

 

pin 6 & 7 output on J1.

 

 

 

 

switch closure

 

Solid State Relay Output

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

NO

YES

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace Air

 

 

Replace Controller

Replace failed component.

 

 

 

 

Ignition Relay Board

Check .8” - 1.2”W.C.

YES

Pressure Switch

 

 

 

 

 

-OR-

Air output on plenum

 

 

 

 

 

 

 

 

 

Replace Ignition

 

Solid State Relay

from blower.

 

 

 

 

 

 

 

 

 

 

 

 

 

Module

 

 

NO

 

 

 

 

YES

 

 

Check for any obstructions

Is Ignition Module

NO

 

Check for 120 VAC at

 

in air ￿ow, if none found

 

Sparking?

Ignition Module, terminals

 

replace blower

 

 

 

 

VALVE & VALVE

 

 

 

YES

 

 

 

NO

 

 

 

 

 

 

 

 

Proceed to Technical Troubleshooting

 

 

 

 

 

“Controller Displays IGNITION

 

 

Check wiring between

 

 

FAILURE” - Ignition Module

 

 

air pressure switch

 

 

 

Is Sparking

 

 

and Ignition Module.

 

Page 44

Part # JIBSM08 Rev 7 (08/04/09)

Page 44
Image 44
Garland XG36-JIB, XG24-JIB service manual Controller Displays Ignition Failure No flame at all, Yes