TECHNICAL TROUBLESHOOTING continued

Controller Displays “IGNITION FAILURE” - Module is sparking, flame comes on and goes out

Dig Gas Valve Open?

Check for 120 VAC across gas NO Valve, terminal 3&4

YES

Check for 3.5”W.C. (NAT

GAS), 10”W.C. (LP) NO burner pressure.

YES

Check gas view port

YES

to ensure ￿ame is lighting.

 

Is Burner lighting at all?

 

NO

 

Check for any obstructions

 

in gas piping and repair

 

as needed

 

Check for 120VAC output from

Check wiring connections

ignition module, terminal

YES

between Ignition Module,

VALVE & VALVE.

 

and Gas Valve.

 

 

NO

 

YES

Adjust gas

Replace Ignition

Replace gas

pressure

Module

valve

Check micrpamp reading between

Ignition Module and Ignitor. UA

Reading should be between .8 and 1.6

Ideal microamps is between 1.0 and 1.2

NOYES

Adjust UA reading until

recommended UA areReplace Ignitor obtained.

Part # JIBSM08 Rev.6 (08/04/09)

Page 45

Page 45
Image 45
Garland XG24-JIB, XG36-JIB service manual Yes, Noyes