TECHNICAL TROUBLESHOOTING continued

Controller Displays “HEATING ERROR or PROBE ERROR PLATEN and GRILL LED’s are RED (Both Sides)

NO

See Technical Troubleshooting

“Controller display is BLANK,

Main Power (ON/OFF) Light IS LIT”

Check for 3-phase voltage at

primary side of main contactors

NO

Check to ensure that 3-phase

power cords are securely fastened and plugged into their receptacles

NO

Fasten & plug in

3-phase power cords

 

Check for 3-phase voltage

 

YES

at secondary side of contactor

Check for disconnected

YES

 

 

 

molex plugs going to heating elements

Ensure that main 3-phase

YES circuit breakers are not tripped or turned o￿

Inconsistent Or Erratic Internal Product Temperature

Grill temperature probes

 

Re-calibrate grill temperature

YES

probes per calibration procedure

are out of calibration

 

See CALIBRATION Section

 

 

NO

 

 

Carbon build up on grill surface

or behind Te￿on release sheets YE S on upper platen

NO

Upper platen is not zeroed properly

YES

Clean grill surface and / or clean upper platen of carbon build up

Zero Platen on e￿ected zone see PLATEN ZEROING Section

Page 40

Part # JIBSM08 Rev 7 (08/04/09)

Page 40
Image 40
Garland XG36-JIB, XG24-JIB Inconsistent Or Erratic Internal Product Temperature, Upper platen is not zeroed properly