TECHNICAL TROUBLESHOOTING continued
Controller Displays “HEATING ERROR or PROBE ERROR PLATEN and GRILL LED’s are RED (Both Sides)
NO
See Technical Troubleshooting
“Controller display is BLANK,
Main Power (ON/OFF) Light IS LIT”
Check for
primary side of main contactors
NO
Check to ensure that
power cords are securely fastened and plugged into their receptacles
NO
Fasten & plug in
| Check for |
| |
YES | at secondary side of contactor | Check for disconnected | |
YES | |||
| |||
|
| molex plugs going to heating elements |
Ensure that main
YES circuit breakers are not tripped or turned o
Inconsistent Or Erratic Internal Product Temperature
Grill temperature probes |
| ||
YES | probes per calibration procedure | ||
are out of calibration | |||
| See CALIBRATION Section | ||
|
| ||
NO |
|
|
Carbon build up on grill surface
or behind Teon release sheets YE S on upper platen
NO
Upper platen is not zeroed properly | YES |
Clean grill surface and / or clean upper platen of carbon build up
Zero Platen on eected zone see PLATEN ZEROING Section
Page 40 | Part # JIBSM08 Rev 7 (08/04/09) |