GEH-6385 Reference and Troubleshooting, 2300 V Drives Chapter 3 Paramters/Functions
3-5
The following variable is also an input to the Capture Buffer function.
Variable Description
Capture buffer ready Enables or disables the capture buffer data
collection.
Function Outputs
The following table sp ecifies the status variables of th e Capture Buffer function.
Variable Description
Capture buffer stat Indicates the status of the capture buffer. Possible
values are:
Complete - Capture buffer has completed its
collection of data and is disabled.
Wait for trigger - The capture buff er is waiting for the
evaluation of the trigger condition to go True.
Post trigger capt – Capture buffer has been tri ggered
and is collecting post trigger data.
Capture triggered Indicates if the capture buffer has been triggered.
True/False
Number of channels Indicat es the number of ch annels that the c apture
buffer is configured to collect based on the setting of
Capture buff config.
Capture buffer depth Indicates the depth (i.e. number of samples) of the
capture buffer. Capture buffer depth is inversely
proportional to the number of channels collected.
Capture samp period Indicat es the interval a t which the captur e buffer
collects data based on the values of the parameters
Capture period and Capture period gain. Seconds
Total capture time Indicates the total time that a full buffer would collect
based on the v alues of Capture b uffer depth,
Capture period, and Capture period gain.