Graco 3A0868G Ranges for User Inputs, Screen User Input Range/Options Default

Models: 3A0868G

1 74
Download 74 pages 34.71 Kb
Page 24
Image 24

Display Module

Ranges for User Inputs

This table is a one-sheet reference of the data range/options accepted for each user input and the default setting. See the page indicated in the table for further screen information, if needed.

Page

Screen

User Input

Range/Options

Default

 

 

 

 

 

39

Run Mix Batch (3)

Target Volume

1 to 9999 cc

0 cc

 

 

 

 

 

40

Run Job Number (38)

User Number

000000000 to 999999999

000000000

 

 

 

 

 

42

Password (16)

Password

0000 to 9999

0000 (disabled)

 

 

 

 

 

43

Configure 1 (18)

System Type

Meters; 50cc Pump; 75cc Pump; 100cc Pump;

Meters

 

 

 

125cc Pump; 150cc Pump

 

43

Configure 1 (18)

Gun Flush Box Enable

On or Off

Off

 

 

 

 

 

43

Configure 1 (18)

Number of Guns

1 or 2 guns

1 gun

 

 

 

 

 

43

Configure 2 (19)

Gun 1 or Gun 2 hose length

0.1 to 45.7 m / 0.3 to 150 ft

1.53 m / 5.01 ft

 

 

 

 

 

43

Configure 2 (19)

Gun 1 or Gun 2 hose diameter

0.1 to 1 inch

0.25 inches

 

 

 

 

 

43

Configure 2 (19)

Flow Rate Region

High (250 cc/min or higher) or

High

 

 

 

Low (<250 cc/min)

 

43

Configure 2 (19)

Air Flow Switch

On or Off

On

 

 

 

 

 

44

Configure 3 (20)

USB Log Language

Chinese; Dutch; English; French; German; Ital-

English

 

 

 

ian; Japanese; Korean; Portuguese;

 

 

 

 

Russian; Spanish; Swedish;

 

 

 

 

 

 

44

Configure 3 (20)

Date Format

mm/dd/yy;

mm/dd/yy

 

 

 

dd/mm/yy;

 

 

 

 

yy/mm/dd

 

 

 

 

 

 

44

Configure 3 (20)

Date

01/01/00 to 12/31/99

Set at factory

 

 

 

 

 

44

Configure 3 (20)

Time

00:00 to 23:59

Set at factory

 

 

 

 

 

44

Configure 3 (20)

Password

0000 to 9999

0000 (disabled)

 

 

 

 

 

44

Configure 3 (20)

Backlight Timer

0 to 99 minutes

0 minutes

 

 

 

 

 

44

Configure 4 (21)

Distance Units

Feet/inches or Meters/cm

Feet/inches

 

 

 

 

 

44

Configure 4 (21)

Volume Units

Liters; Gallons US; Gallons Imperial

Gallons US

 

 

 

 

 

44

Configure 4 (21)

Pressure Units

psi; Bar; MPA

psi

 

 

 

 

 

44

Recipe 1-1 (28)

Ratio

0:1 to 30:1

1:1

 

 

 

Note: Enter 0 to dispense A only.

 

44

Recipe 1-1 (28)

Ratio Tolerance

1 to 99 percent*

5 percent

 

 

 

 

 

44

Recipe 1-1 (28)

Potlife Timer

0 to 240 minutes

60 minutes

 

 

 

Note: If set to 0, potlife alarm is disabled.

 

44

Recipe 1-2 (29)

Flush Times- First (A purge),

0 to 240 seconds

60 seconds

 

 

Second (B purge), or Third

Note: If set to 0, the valve(s) will not flush.

 

 

 

(using A or B, chosen by user)

 

 

 

 

 

 

 

45

Maintenance 1 (24)

Pump A or Pump B

0 to 9,999,999

0

 

 

 

 

 

45

Maintenance 1 (24)

Solvent Valve A or Solvent

0 to 9,999,999

0

 

 

Valve B

 

 

 

 

 

 

 

45

Maintenance 2 (25)

Dose Valve A or Dose Valve B

0 to 9,999,999

0

 

 

 

 

 

45

Maintenance 3 (26)

Fluid Filter A or B, or Air Filter

0 to 9999 days

0 days

 

 

 

 

 

46

Calibration 1 (22)

Pump A or Pump B Factor

5 to 50 cc/in

50cc: 10 cc/in.

 

 

 

 

75cc: 15 cc/in.

 

 

 

 

100 cc: 20 cc/in.

 

 

 

 

125cc: 25 cc/in.

 

 

 

 

150cc: 30 cc/in.

 

 

 

 

 

46

Calibration 2 (23)

Actual Dispensed Volume

1 to 9999 cc

0 cc

 

 

 

 

 

*The system will attempt to hold whatever accuracy is entered. For some ratios and applications, testing shows that actual sys- tem accuracy may be ±2% or ±5%. See Technical Data, page 73.