System Errors

Alarm and Description

Cause

Solution

 

 

 

SFA1 or SFB1

Gun, line, or valve is plugged or stuck.

Check components and clean, repair,

PreMix Error

 

or replace as necessary.

In systems with a gun flush

 

 

Pump(s) not working or out of fluid.

Refill fluid supply. Check and repair

box, insufficient quantity of

 

pump. See pump manual for repair

resin/color (SFA1) or catalyst

 

procedures and replacement parts.

(SFB1) is detected during the

 

 

Air lines or solenoids are plumbed incor-

Check air line path. See System

10-second PreMix sequence.

rectly or solenoids are not working.

Pneumatic Schematic, page 66 or

 

SHA1 or SHB1

 

67. Verify that solenoid is working.

 

 

Flow rate is too low.

Increase fluid pressure.

PreFill Error

Total PreFill sequence volume

 

 

is not reached for color

 

 

(SHA1) or catalyst (SHB1)

 

 

during the 5-minute PreFill

 

 

sequence.

 

 

 

 

 

SM

Gun Flush Box is not triggering gun.

Verify trigger is being pulled. Adjust

MixFill Start Error

 

as needed.

In systems with a gun flush

 

 

Line or gun is plugged or restricted.

Clean line, tip, or filter.

box, insufficient volume of

 

 

Flow rate is too low.

Increase fluid pressure or decrease

mixed material is detected

 

restriction.

during the 10-second mixed fill

 

 

 

Valve is stuck.

Clean valve or verify that solenoid is

sequence.

 

 

triggering valve properly.

SN

 

 

MixFill Complete Error

 

 

Insufficient volume of mixed

 

 

material is detected during the

 

 

5-minute mixed fill sequence.

 

 

 

 

 

QPD1 or QPD2

Have not sprayed enough volume to keep

Purge the mixed material line. See

Potlife Error

fresh mixed fluid in the mix manifold, hose,

page 33.

Potlife has been exceeded for

and gun.

Check that hose length and diameter

the mixed material for Gun 1

 

(QPD1) or Gun 2 (QPD2).

 

have been entered correctly. See

 

 

Configure 2 (Screen 19), page 43.

 

 

Spray the required volume to restart

 

 

the potlife timer.

 

 

 

3A0868G